Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
HNO ; 72(4): 291-302, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38351342

RESUMO

Idiopathic sudden sensorineural hearing loss (ISSNHL) is one of the most common diseases in otolaryngology. Its etiology remains unknown. Furthermore, there is only a low level of evidence for the efficacy of established treatment modalities. In addition to systemic glucocorticoids, intratympanic corticosteroid treatment (ICT) has become increasingly important for treatment of ISSNHL. Different application strategies and treatment regimens have been described; however, uniform standards do not yet exist. ICT may be used for primary treatment as well as salvage therapy. Current data from meta-analyses show no benefit of intratympanic versus systemic primary therapy for sudden hearing loss (moderate evidence) but suggest a benefit of intratympanic secondary treatment over no treatment or placebo (high effect size, low evidence). Regarding combination of systemic and local glucocorticoid therapy in primary treatment of hearing loss, there may be a small benefit over systemic treatment alone (low effect size, low evidence).


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Humanos , Glucocorticoides , Perda Auditiva Súbita/diagnóstico , Perda Auditiva Súbita/tratamento farmacológico , Dexametasona/uso terapêutico , Resultado do Tratamento , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/tratamento farmacológico , Perda Auditiva Neurossensorial/etiologia , Corticosteroides/uso terapêutico , Injeção Intratimpânica , Audiometria de Tons Puros/efeitos adversos
2.
PLoS One ; 17(11): e0268863, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36350807

RESUMO

BACKGROUND: The reprocessing of daily used medical devices is often inadequate, making them a potential source of infection. In addition, there are usually no consistent and technically standardized procedures available for this purpose. Hence, the aim of this study is to analyze the bacterial contamination and the effectiveness of Ultraviolet light-based (UV light-based) reprocessing of daily used medical devices. MATERIAL AND METHODS: Six different everyday medical devices (20 each; stethoscopes, tourniquets, bandage scissors, reflex hammers, tuning forks, and nystagmus glasses) were tested for bacterial contamination. All medical devices were then exposed to UV-C light for 25 seconds. Medical devices with a smooth surface were pre-cleaned with a water-based wipe. Contact samples were taken before and after reprocessing. RESULTS: Immediately after clinical use, 104 of 120 contact samples showed an average bacterial contamination of 44.8±64.3 colony forming units (CFU) (0-300 CFU), also including potentially pathogenic bacteria. Two further culture media were completely overgrown with potentially pathogenic bacteria. The stethoscopes were found to have the highest average contamination of 90±91.6 CFU. After reprocessing, 118 of 120 samples were sterile, resulting in an average residual contamination of 0.02±0.1 CFU in two samples, whereby only bacteria of the ordinary skin flora were found. CONCLUSION: The present study shows the potentially clinically relevant bacterial contamination of everyday used medical devices. The reprocessing method tested here using UV light appears to be a suitable method for disinfection, especially for objects that up to now have been difficult to disinfect or cannot be disinfected in a standardized manner.


Assuntos
Contaminação de Equipamentos , Raios Ultravioleta , Contaminação de Equipamentos/prevenção & controle , Desinfecção/métodos , Bactérias , Contaminação de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...